13. Data Storage for System Diagnostics
The following data is stored by the thermostat to allow advanced system diagnostics:
Average cooling set-point while cooling is active (“SC”)
Average heating set-point while heating is active (“SH”)
Average number of cooling cycles per day while in cooling mode (“CC”)
Average number of heating cycles per day while in heating mode (“CH”)
Average length of cooling cycle in minutes (“LC”)
Average length of heating cycle in minutes (“LH”)
These values are cumulative from the time the thermostat is placed into service.
To access these values follow these steps:
1. Press and hold (6 seconds) the On/Off button to set the
system mode to OFF
2. Using the “+” and “-“ buttons set the temperature set-point
to 55°F.
3. When the display stops flashing, press and hold the Select
button.
4. Use the Select button to advance through the steps.